Size
Between 3 to 6 inches
Size
Between 3 to 6 inches
Material
Stainless Steel, Other
Temperature
Between -30°c to 220°c
Type
Top Loading Arm
The Long Range Jacketed Top Loading Arm with Rigid Vapour Recovery is designed for safe and efficient transfer of volatile chemicals. Twin pipelines handle liquid filling and vapour return, while the recovery cone and drip bucket prevent emissions and spills. Four base and two double swivel joints provide smooth manoeuvrability for precise positioning, ensuring reliable, flexible chemical loading operations.
The Tandem Long Range Jacketed Top Loading Arm with Rigid Vapour Recovery is specifically designed for the safe transfer of volatile chemicals. It features twin pipelines for liquid filling and vapour return, along with a vapour recovery cone to capture harmful emissions and improve operational safety.
The arm incorporates four Style 40 base swivel joints and two Style 70 double swivel joints, providing smooth horizontal and vertical movement for precise positioning. At the end of the loading arm, a hooking drip bucket is fitted to catch any hot product, preventing contact with the surrounding environment and ensuring a cleaner, safer operation.
Flow rates for the Tandem Long Range Jacketed Top Loading Arm with Rigid Vapour Recovery are:
This combination of features makes this Top Loading Arm with Rigid Vapour Recovery a reliable and efficient solution for handling hazardous chemicals, offering both safety and operational flexibility.
Tel: +44 (0) 1763 248 650
Email: sales@ewfm.co.uk
To keep up to date with news on how we are supporting our customers, our latest blogs and new services available, keep checking in on our website throughout the year and follow us on social media.
Available Sizes:
3″ x 2″ / 4″ x 3″ / 6″ x 4″
Material:
Stainless Steel
Operating Conditions:
Design Pressure 10.0 Bar G
Test Pressure 15.0 Bar G
Temperature:
-15° C / +200°C
Seal Material:
PTFE
Accessories:
Locking device arm in parking position
Stand post C-4928-A Model
Double level sensors
Electronic level sensor instead pneumatic type
Insulation
NDT test (RT-PT-MT) available on request
We can visit your site to inspect your systems, identify optimisation opportunities, and recommend the best-engineered solutions.